Push-button test
The test button confirms the RCD mechanism trips and cuts power. It is the quick check, but it does not tell you how fast.
Servicing regional VIC and Southern NSWKyabram based, servicing regional Victoria and Southern NSW
Electrical safety, Kyabram
Safety switches tested for Kyabram workplaces, farms, clubs and schools. We time every trip, record the result and tell you straight away if one is failing.
An RCD is meant to cut the power in a fraction of a second when current leaks to earth, which is what happens when someone touches a live part. They can stick or slow down over the years, and from the outside they look exactly the same.
We test them the way AS/NZS 3760 sets out: a push-button test and a timed trip test with a proper RCD tester. Being based in Kyabram, we can test your switchboard and portable RCDs on the same visit as your test and tag.
Switchboard safety switches and portable RCDs both get tested. An RCD that looks fine and does not trip is worse than none, because everyone thinks they are covered.
The test button confirms the RCD mechanism trips and cuts power. It is the quick check, but it does not tell you how fast.
With an RCD tester we put a measured fault on the circuit and time the trip. A standard 30 mA RCD should cut power within 300 milliseconds.
Fixed safety switches in your switchboard are tested and labelled, and we note which circuits each one protects.
Plug-in and lead-mounted RCDs used on tools and outdoor gear are tested and tagged along with the rest of your portable equipment.
We record every trip time, so we can compare this visit with the last one. A unit getting slower is often on its way out.
Results go into your report. If an RCD fails or is borderline, we tell you so a licensed electrician can replace it.
Intervals depend on the type of RCD and where it is used. Construction sites and other tough environments are tested more often. We set the schedule for your site and remind you when it is due.
Regularly, often every three to six months, to confirm the RCD still trips.
At least yearly in most workplaces, measuring how fast each RCD cuts the power.
If an RCD keeps tripping or will not reset, get it checked before relying on it again.
A few habits that keep your safety switches doing their job.
One booking, one report.
Call or send a request. We book a visit that suits your hours and work around your team.
Every extinguisher, light, appliance and kit checked and tagged. Problems are pointed out while we are there.
You get a written report, and we contact you before the next service falls due.
We test RCDs across Kyabram, Tongala, Merrigum, Stanhope and Tatura, for workplaces, farms and community buildings.
Also in: Shepparton, Echuca
If the shed is a workplace, yes. Sheds, dairies and workshops are hard on electrical gear and often wet, which is exactly where an RCD matters most. We test switchboard RCDs and the portable ones on your leads.
Yes. Most local sites book both together. It saves a second visit and puts all your electrical results in one report.
A circuit breaker protects the wiring from overloads. An RCD (often called a safety switch) protects people, by cutting power fast when current leaks to earth, like through someone touching a live part.
Pressing the button is a good habit and tells you the RCD trips. It does not tell you how quickly. A timed trip test with an RCD tester is the only way to confirm it trips fast enough to protect someone.
We note it in your report and let you know on the day. Fixed switchboard RCDs need replacing by a licensed electrician. Faulty portable RCDs are tagged out of service.
Yes, and most sites do. RCD testing, test and tag, fire equipment and emergency lighting can all be done in one visit with one report.
Tell us what you have on site and we will come back to you with a time and a clear quote. Prefer to talk? Call Paul.
Fields marked * are required.
Thanks, request sent.
We will be in touch within business hours (Mon to Fri, 8 AM to 4 PM) with a time and a quote. Need us sooner? Call 0407 877 482.